Water Immersion

ISO 12944 on ZINGA + Zingaceram HS + Zingaceram EP

ISO 12944-6: Paints and varnishes — Corrosion protection of steel structures by protective paint systems
The ISO 12944 standard is intended to assist engineers and corrosion experts in adopting best practice in corrosion protection of structural steel with coatings at new construction and repairs. ISO 12944 is progressively superseding regional standards to become a truly global benchmark in corrosion control.

The ZINGA/Zingaceram HS/Zingaceram EP system has been subjected to extensive testing such as water condensation
test, neutral salt spray test, chemical resistance test and water immersion test. After a prescribed exposure test (depending on representative environment), the coating is assessed for adhesion, blistering, rusting, cracking and flaking.

Environments are classified according corrosivity:

  • C1: Indoor conditions (Heated buildings/neutral atmosphere)
  • C2: Rural areas, low pollution (countryside, inland town areas)
  • C3: Urban and industrial atmospheres with moderate sulphur dioxide levels and salinity. Production areas with high humidity (inland big cities with high traffic)
  • C4: Industrial or coastal (with moderate salinity) zones (chemical factories, swimming pools, shipyards)
  • C5I: Industrial zones with high humidity and aggressive environment (continuous condensation and high pollution)
  • C5M: Coastal zones and marine zones with high salinity (continuous condensation and high pollution)

After exposure, the coating is evaluated as H(igh), M(edium) or L(ow); reflecting in a life expectancy of:
Low: Life expectancy less than 5 years
Medium: Life expectancy between 5 and 15 years
High: Life expectancy more than 15 years

The system

ZINGA 1 x 60-80 µm DFT

+

Zingaceram HS 1 x 120 µm DFT

+

Zingaceram EP 1 x 60 µm DFT

passed the tests for C5I and C5M with a High Classification.

ISO 12944 on ZINGA + Zingaceram HS + Zingaceram PU

ISO 12944-6: Paints and varnishes — Corrosion protection of steel structures by protective paint systems
The ISO 12944 standard is intended to assist engineers and corrosion experts in adopting best practice in corrosion protection of structural steel with coatings at new construction and repairs. ISO 12944 is progressively superseding regional standards to become a truly global benchmark in corrosion control.

The ZINGA/Zingaceram HS/Zingaceram PU system has been subjected to extensive testing such as water condensation
test, neutral salt spray test, chemical resistance test and water immersion test. After a prescribed exposure test (depending on representative environment), the coating is assessed for adhesion, blistering, rusting, cracking and flaking.

Environments are classified according corrosivity:

  • C1: Indoor conditions (Heated buildings/neutral atmosphere)
  • C2: Rural areas, low pollution (countryside, inland town areas)
  • C3: Urban and industrial atmospheres with moderate sulphur dioxide levels and salinity. Production areas with high humidity (inland big cities with high traffic)
  • C4: Industrial or coastal (with moderate salinity) zones (chemical factories, swimming pools, shipyards)
  • C5I: Industrial zones with high humidity and aggressive environment (continuous condensation and high pollution)
  • C5M: Coastal zones and marine zones with high salinity (continuous condensation and high pollution)

After exposure, the coating is evaluated as H(igh), M(edium) or L(ow); reflecting in a life expectancy of:
Low: Life expectancy less than 5 years
Medium: Life expectancy between 5 and 15 years
High: Life expectancy more than 15 years

The system

ZINGA 1 x 60-80 µm DFT

+

Zingaceram HS 1 x 120 µm DFT

+

Zingaceram PU 1 x 60 µm DFT

passed the tests for C5I and C5M with a High Classification.

ISO 12944 on ZINGA + Zingaceram HS

ISO 12944-6: Paints and varnishes — Corrosion protection of steel structures by protective paint systems
The ISO 12944 standard is intended to assist engineers and corrosion experts in adopting best practice in corrosion protection of structural steel with coatings at new construction and repairs. ISO 12944 is progressively superseding regional standards to become a truly global benchmark in corrosion control.

The ZINGA/Zingaceram HS system has been subjected to extensive testing such as water condensation
test, neutral salt spray test, chemical resistance test and water immersion test. After a prescribed exposure test (depending on representative environment), the coating is assessed for adhesion, blistering, rusting, cracking and flaking.

Environments are classified according corrosivity:

  • C1: Indoor conditions (Heated buildings/neutral atmosphere)
  • C2: Rural areas, low pollution (countryside, inland town areas)
  • C3: Urban and industrial atmospheres with moderate sulphur dioxide levels and salinity. Production areas with high humidity (inland big cities with high traffic)
  • C4: Industrial or coastal (with moderate salinity) zones (chemical factories, swimming pools, shipyards)
  • C5I: Industrial zones with high humidity and aggressive environment (continuous condensation and high pollution)
  • C5M: Coastal zones and marine zones with high salinity (continuous condensation and high pollution)

After exposure, the coating is evaluated as H(igh), M(edium) or L(ow); reflecting in a life expectancy of:
Low: Life expectancy less than 5 years
Medium: Life expectancy between 5 and 15 years
High: Life expectancy more than 15 years

The system

ZINGA 1 x 60-80 µm DFT

+

Zingaceram HS 1 x 120 µm DFT

passed the tests for C5I and C5M with a High Classification.

ISO 12944 on ZINGA + Zingalufer

ISO 12944-6: Paints and varnishes — Corrosion protection of steel structures by protective paint systems
The ISO 12944 standard is intended to assist engineers and corrosion experts in adopting best practice in corrosion protection of structural steel with coatings at new construction and repairs. ISO 12944 is progressively superseding regional standards to become a truly global benchmark in corrosion control.

The ZINGA/Zingalufer system has been subjected to extensive testing such as water condensation
test, neutral salt spray test, chemical resistance test and water immersion test. After a prescribed exposure test (depending on representative environment), the coating is assessed for adhesion, blistering, rusting, cracking and flaking.

Environments are classified according corrosivity:

  • C1: Indoor conditions (Heated buildings/neutral atmosphere)
  • C2: Rural areas, low pollution (countryside, inland town areas)
  • C3: Urban and industrial atmospheres with moderate sulphur dioxide levels and salinity. Production areas with high humidity (inland big cities with high traffic)
  • C4: Industrial or coastal (with moderate salinity) zones (chemical factories, swimming pools, shipyards)
  • C5I: Industrial zones with high humidity and aggressive environment (continuous condensation and high pollution)
  • C5M: Coastal zones and marine zones with high salinity (continuous condensation and high pollution)

After exposure, the coating is evaluated as H(igh), M(edium) or L(ow); reflecting in a life expectancy of:
Low: Life expectancy less than 5 years
Medium: Life expectancy between 5 and 15 years
High: Life expectancy more than 15 years

The system

ZINGA 1 x 60-80 µm DFT

+

Zingalufer 1 x 80 µm DFT

passed the tests for C5I and C5M with a High Classification.

NORSOK M-501 Syst 1 & 7 on ZINGA 2 x 60 µm DFT

NORSOK M-501 is an industry standard for adequate surface preparation and use of coating materials, developed with the emergence of the Norwegian oil industry.
ISO 20340 deals with performance requirements for protective paint systems for offshore and related structures (i.e. those exposed to the offshore environment, as well as those immersed in sea or brackish water).

ZINGA has passed the 4200 hours seawater immersion test and the 4200 hours cyclic test without any formation of rust, blisters, cracks, flakes or cathodic disbondment. The pull-off adhesion test on ZINGA resulted in values of more than 7 MPa.

ISO 12944 on ZINGA + Zingatarfree

ISO 12944-6: Paints and varnishes — Corrosion protection of steel structures by protective paint systems
The ISO 12944 standard is intended to assist engineers and corrosion experts in adopting best practice in corrosion protection of structural steel with coatings at new construction and repairs. ISO 12944 is progressively superseding regional standards to become a truly global benchmark in corrosion control.

The ZINGA/Zingatarfree system has been subjected to extensive testing such as water condensation
test, neutral salt spray test, chemical resistance test and water immersion test. After a prescribed exposure test (depending on respresentative environment), the coating is assessed for adhesion, blistering, rusting, cracking and flaking.

Environments are classified according corrosivity for structures in immersion:
• Im1: Clear, fresh or potable water
• Im2: Sea or brackish water (harbors with locks, jetties, offshore structures; make sure there is no stray
current)
• Im3: Soil (underground storage, iron poles)

After exposure, the coating is evaluated as H(igh), M(edium) or L(ow); reflecting in a life expectancy of:
Low: Life expectancy less than 5 years
Medium: Life expectancy between 5 and 15 years
High: Life expectancy more than 15 years

The system

ZINGA 1 x 60-80 µm DFT

+

Zingatarfree 2 x 100 µm DFT

passed the tests for Im2 and Im3 with a High Classification.